SPECIFICATIONS Basic Functions Range Best Accuracy DC Voltage 200mV/2000mV/20V/200V/500V ±(0.5%+2) AC Voltage 200V/500V ±(1.2%+10) DC Current 200mA/200mA/10A ±(1%+2) Resistance 200W/2000W/20kW/200kW/20MW ±(0.8%+2) Special Functions Battery Test 1.5V/9V/12V (2.5%+2) Diode ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-05 02:43:35 ]
II.Functions: 1 Breakdown test of user-defined 2 Proof test 3 Calibration interface for customers 4 Result print III.Technique index: 1 Output voltage: AC 0~80KV 2 Rate of voltage rise: 2KV/s±10% 3 Measuring precision: 3%RDG+0.3%FS 4 Test times setting: 1-9 5 Mixing time ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 07:18:14 ]
I.General introduction GDLB-601 is an instantaneous signal recorder applied in industry signal analysis. It takes IPC as the core for data sample and process. Special design makes the reorder has a good performance in anti-jamming and easy operation. II.Functions 1. All ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 07:16:42 ]
GDZC Max. 5A Transformer Winding Resistance Meter I.Application: GDZC Series winding resistance tester are applied to measure the DC resistance of inductance circuit such as power transformer coil, current transformer coil and so on. Also the tester could be applied to measure ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 07:14:20 ]
II.Main Functions 1) Closing and opening time measurement of 12 channels 2) Max difference of closing or opening time measurement of three phases 3) Bounce time and frequency measurement of breaker closing 4) Circuit breaker closing and opening speed measurement 5) Travel-time, ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 07:12:38 ]
GDJ-II High Precision Insulating Oil Dielectric Loss Tester I.Functions 1. Tangent delta value measurement for insulating oil 2. Capacitor value measurement for insulating oil 3. Temperature control for insulating oil in test vessel 4. Print test results by micro printer ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 07:08:49 ]
GDKF Transformer Load Tester and No-load Tester I. Function Measure the transformer load current, load loss, short-circuit voltage, short circuit (load) losses. II.Test Item RMS phase voltage Average value of three-phase AC voltage Three-phase current RMS Percentage of no-load ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 05:02:23 ]
GDHL-200A Circuit Breaker Contact Resistance Tester I.General introduction Contact resistance tester output DC 200A/100A current to test the contact resistance of circuit breaker or high current cable contacts. It is designed according to IEC62271. The main application of the ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 04:57:06 ]
Application ZGF DC high voltage generator is DC high voltage power supply equipment which is applied in power cable test and arrester test in power system. Technique index Model Item ZGF-60/2 ZGF-120/2 ZGF-120/5 ZGF-200/2 ZGF-300/2/3 ZGF- 200/400/2 Output Voltage 60kV 120kV ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 04:54:01 ]
GDGS High Voltage Electric Equipment Dielectric Loss Tester I.Application GDGS automatic tan delta tester is applied to measure the dielectric loss and capacitor value of insulation materials in high voltage power equipment. The non-power frequency voltage source is integrated ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 04:51:40 ]
I.Functions: 1 Breakdown test of user-defined 2 Proof test 3 IEC60156/IS6792/BS5874 test 4 ASTM D1816 standard test 5 ASTM D877 standard test 6 5 minutes standard test 7 Manual test 8 Calibration interface for customers 9 Uploading data to PC and making word report ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 04:48:26 ]
I.Application: GDHL loop resistance tester is applied in circuit breaker testing and power cable connection quality inspection. The max test current of contact resistance tester could be reached 600A. All the test results could be saved in tester or printed by micro printer. ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 04:47:36 ]
I.Functions 1. The voltage ratio measurement for three or singe phase transformer 2. The group vector measurement for three phase transformer. 3. The polarity measurement for single phase transformer or CT/PT 4. Voltage ratio error calculation 5. Current transformer ratio ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 04:46:18 ]
I.Application GDDZ insulating gloves and boots is application to test leakage current,insulation aging,power frequency of insulating gloves and boots. It can test 3 paris for each time and to read leakage current of each pair in order to find which one is unqualified.There are ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 04:45:11 ]
I.Functions: 1 Breakdown test of user-defined 2 Proof test 3 IEC60156/IS6792/BS5874 test 4 ASTM D1816 standard test 5 ASTM D877 standard test 6 5 minutes standard test 7 Manual test 8 Calibration interface for customers 9 Uploading data to PC and making word report ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 04:43:45 ]
Transformer oil tests: Transformer oil test methods: Gas (CH4-1,CH4-2,CO,CO2,C2H2,C2H4,C2H6,O2,H2)in Transformer oil Gas chromatography method Appearance at 15°C ASTM D4176 Water Content ASTM D1533B, D6304 Density at 15°C ASTM D4052 Specific Gravity ASTM 4052 Suspended ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 04:41:47 ]
I---General Information VLF means ‘Very Low Frequency’ and 0.1Hz to 0.02Hz is considered to be very low frequency,used as a AC output tester. Although the frequency is very low, it is still an alternating current with polarity reversals every half cycle. At 0.1 Hz output, ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 04:34:46 ]
The Output capacity and voltage can be customized according to request. Rapid test forAC impedance and characteristic curve of Generator under dynamic and static condition. Automatic-collect ,test, display ,save, print all the test data(voltage, current, impedance, ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 04:32:16 ]
>>Application SLQ Strong current Generator is a high current generator instrument. It is applied in current transformer test , circuit breaker test and so on. >>Technique index Type Capacity (kva) Power supply Output Impedance voltage % Idle current % mode I (A) V (V) I (KA) V ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 04:30:41 ]
I.Functions: 1. Breakdown test of user-defined 2. Proof test 3. Calibration interface for customers 4. Uploading data to PC and making word report automatically. 5. Result print II.Technique index: 1. Output voltage: AC 0~80KV/AC 0~100KV 2. Rate of voltage rise: 2KV/s±10% 3. ...
ChongQing Gold Machine& Electric Equipment Co., Ltd. [Measurement & Analysis Instruments] [Electronic Measuring Instruments] [2014-03-04 04:28:04 ]